About OVO Processes<br />

About Management Server Processes<br />

About Management Server Processes<br />

This section describes OVO processes and their associated files on the<br />

management server.<br />

Types of Processes on the Management Server<br />

This section describes the processes that run on the OVO management<br />

server.<br />

opc OVO GUI logon program that is used by the OVO<br />

administrator and operators. The program calls either<br />

opcuiadm and opcuiopadm or opcuiop, according to<br />

the user name specified.<br />

opcactm Action manager that feeds the action agents with<br />

automatic actions, operator-initiated actions, scheduled<br />

actions, and application startup and broadcasting<br />

information through the control agent. In addition,<br />

external instructions are determined using this<br />

mechanism.<br />

ovoareqsdr Request sender that informs the control agents to<br />

start, stop, or update their local OVO agents. The<br />

request sender is also responsible for the<br />

self-monitoring of OVO manager services, and for the<br />

heartbeat-polling of the managed nodes.<br />

opcctlm Control manager that starts and stops all other OVO<br />

manager processes, performs all licence checking, and<br />

controls OVO database maintenance.<br />

opcdispm Display manager that serves the OVO Motif-based<br />

GUI. The display manager also feeds the action<br />

manager with operator-initiated actions, application<br />

startup information (not requiring a separate<br />

terminal), and broadcasting information issued by<br />

operators. Several OVO user GUIs may be active at the<br />

same time, but only one Motif-based GUI can be run for<br />

each operator.<br />