Safeguard Catalogue - Personnel Remarks<br />

____________________________________________________________________ .........................................<br />

S 3.20 Instructions concerning the operation of<br />

protective cabinets<br />

Initiation responsibility: <strong>IT</strong> Security Management<br />

Implementation responsibility: <strong>IT</strong> security management, manufacturer<br />

Following the purchase of a protective cabinet, users must be familiarised with<br />

correct operation. This should also occur when a task involving use of the<br />

protective cabinet is reassigned. As a minimum requirement, the following<br />

points must be conveyed:<br />

- Correct procedure with the lock of the protective cabinet must be<br />

demonstrated. Typical errors should be pointed out, for example not wiping<br />

code locks. <strong>The</strong> rules governing key management, safekeeping of keys and<br />

replacement regulations must be outlined. In particular, individuals must be<br />

called on to lock the protective cabinet when not in use, even for a short<br />

period.<br />

- <strong>The</strong> keyboard of a server must always be kept in the server cabinet so that<br />

no unauthorised console inputs can be made.<br />

- As far as server cabinets are concerned, it should be pointed out that<br />

unnecessary inflammable materials (print-outs, surplus manuals, printer<br />

paper) should not be kept in the server cabinet.<br />

- Data backup media of the server should be stored in another fire zone.<br />

Keeping them in the server cabinet is therefore inappropriate and only<br />

permissible if a duplicate of the data backup medium is relocated to<br />

another fire zone.<br />

- If an air-conditioned server cabinet is used, the times the server cabinet is<br />

open should be kept to a minimum. Where necessary, sporadic checks<br />

should be carried out to determine whether there is any water condensation<br />

in the server cabinet.<br />

Additional controls:<br />

- Have people in charge of a protective cabinet been familiarised with its<br />

operation?<br />