Safeguard Catalogue - Organisation Remarks<br />

____________________________________________________________________ .........................................<br />

S 2.20 Monitoring of existing connections<br />

Initiation responsibility: Head of <strong>Site</strong>/Bldg Technical Service, Head of<br />

<strong>IT</strong> Section<br />

Implementation responsibility: Head of <strong>Site</strong>/Bldg Technical Service; network<br />

planner<br />

A visual inspection (at least on a random basis) must be made of all<br />

distributors and duct boxes. Attention must be paid to the following aspects:<br />

- traces of attempts to open locked distributors by force;<br />

- up-to-date information provided in the documentation placed in the<br />

distributors;<br />

- correspondence of actual line assignments and strap connections with the<br />

information provided in the documentation;<br />

- integrity of the short-circuits and grounding of non-required circuits; and<br />

- inadmissible installations/modifications.<br />

A functional check can be made in addition to the mere sight check. For this<br />

purpose, existing lines will be reviewed for their necessity and for compliance<br />

with technical parameters. Such a review is advisable in the following<br />

situations:<br />

- in the case of lines which are very seldom used and where manipulations<br />

are not detected at once;<br />

- in the case of lines over which sensitive information is transmitted<br />

frequently and regularly.<br />

Additional controls:<br />

- At what intervals are existing connections being checked?<br />

- How are identified irregularities documented and followed up?<br />

- To whom must such irregularities be reported?<br />

- Who will remedy any irregularities, and who will monitor such work?<br />

____________________________________________________________________ .........................................<br />

<strong>IT</strong>-<strong>Baseline</strong> <strong>Protection</strong> <strong>Manual</strong>: Oktober 2000