Safeguard Catalogue - Organisation Remarks<br />

____________________________________________________________________ .........................................<br />

Levels, which are listed below. Each level contains the functionalities of the<br />

previous levels.<br />

- SFT I (System Fault Tolerance I)<br />

Novell Netware 3.x supports SFT I as standard. This level prevents loss of<br />

data due to physical hard disk problems. After a write access to a file, the<br />

stored data on the disk is compared to the still available memory image on<br />

the Netware server. If the data do not compare, the sector of the hard disk<br />

will be marked as faulty and will be locked for future access.<br />

<strong>The</strong> data is then stored in a ”Hot Fox Area” on the hard disk. Within<br />

Novell Netware this area occupies two percent of the disk as a standard.<br />

- SFT II (System Fault Tolerance II)<br />

SFT II can be implemented in two different ways.<br />

- Disk Mirroring (System Fault Tolerance II)<br />

For disk mirroring two identical hard disks are connected to the<br />

same controller of a server. <strong>The</strong> data is stored simultaneously on<br />

both hard disks. If one disk fails, the second disk will be used<br />

without a loss in availability.<br />

- Disk Duplexing (System Fault Tolerance II)<br />

Disk Duplexing means the installation of two hard disks and their<br />

controllers. With this mechanism not only a hard disk failure can be<br />

remedied, but also the failure of a hard disk controller can be<br />

recovered.<br />

- SFT III (System Fault Tolerance III)<br />

SFT III is the highest level of tolerance for hardware faults that arise<br />

during operation. Two identical Novell Netware servers operate<br />

simultaneously and parallel to one another within the network.<br />

<strong>The</strong> servers are connected via their own high speed network. If one server<br />

breaks down, operation of the network can be continued with the second<br />

server almost without loss of time and data.<br />

<strong>The</strong> decision as to whether or not additional measures will be needed besides<br />

level I is dependent upon the required level of availability in the network.<br />

Uninterruptible Power Supply (USP)<br />

By using an uninterruptible power supply (UPS), the consequences of a power<br />

failure can be remedied. Netware supports the utilisation of devices supporting<br />

UPS-Monitoring. In case of a power failure the server will be shut down at the<br />

end of the lifetime of the UPS in an orderly manner. All data residing in<br />

caches are written to hard disks. Connections to servers are terminated, as are<br />

server processes.<br />

Additional controls:<br />

- Is the documentation sufficient for a substitute administrator?<br />

- How has the choice of SFT level been justified?<br />

____________________________________________________________________ .........................................<br />