Safeguard Catalogue - Organisation Remarks<br />

____________________________________________________________________ .........................................<br />

SERVER TIME<br />

TYPE<br />

Hamburg-S1 Reference Main<br />

partition<br />

Hamburg-S2 Secondary Read/write<br />

replication<br />

____________________________________________________________________ .........................................<br />

<strong>IT</strong>-<strong>Baseline</strong> <strong>Protection</strong> <strong>Manual</strong>: Oktober 2000<br />

PART<strong>IT</strong>IO<br />

NS<br />

[Root] Public Hamburg Berlin<br />

Main<br />

partition<br />

Read/write<br />

replication<br />

Hamburg-S3 Secondary Main<br />

partition<br />

Berlin-S1<br />

Berlin-S2<br />

Primary<br />

Primary<br />

Read/write<br />

replication<br />

Read/write<br />

replication<br />

Main<br />

partition<br />

Read /<br />

write<br />

replication<br />

Hardware configuration<br />

It should be noticed here that, during a new installation of a Netware server<br />

(e.g. following a system crash), all details concerning the hardware settings<br />

must be known in order to allow quick and proper re-configuration of the<br />

server. If these settings are not known, they need to be scanned using<br />

appropriate programs or read off on the device, which proves quite timeconsuming.<br />

This applies especially to the rectification of time-critical errors.<br />

As concerns each of the hardware components used on the server, such as<br />

network adapter cards, graphic cards, communications interfaces (serial,<br />

parallel, USB, PS/2) as well as SCSI, IDE and RAID controller, the following<br />

information must be recorded, among others:<br />

- Interrupt<br />

- I/O interface<br />

- DMA channel<br />

- SCSI and LUN address<br />

- Memory address<br />

- Node address<br />

- Slot number<br />

- External IPX network number<br />

- Frame type<br />

<strong>The</strong> documentation of the server hardware must also cover external devices<br />

such as<br />

- Printers and