COMFLTFORCOMINST 4790.3 REV A<br />

SAMPLE PRE-COMMISSIONING HABITABILITY<br />

INSPECTION CHECK LIST FOR NEW CONSTRUCTION SHIPS (Cont'd)<br />

Compartment Number: Division:____________________________<br />

2. Pump Room Safety<br />

a. Slightly negative pressure exhaust ventilation with duct installed<br />

9 inches from the deck in CHT pump rooms (NAVMED P-5010,<br />

Chapter 7, Article 22 and NSTM 512).<br />

b. Indicator light installed outside compartment indicating ventilation<br />

system is operating (NAVMED P-5010, Chapter 7, Article 22).<br />

c. Two emergency escape breathing devices (EEBD) placed in each<br />

CHT pump room (NAVMED P-5010, Chapter 7, Article 22 and<br />

NSTM 593, Section 4.2.21.3.1.4).<br />

d. Placard installed at the access of each CHT pump room outlining<br />

safety precautions to be followed if a sewage spill occurs (NAVMED<br />

P-5010, Chapter 7, Article 22d).<br />

e. Warning sign posted near each sewage pump controller: "CAUTION,<br />

WHEN HIGH LEVEL ALARM SOUNDS DIVERT UPPER DECK<br />

DRAINS OVERBOARD AND CLOSE ISOLATION VALVES ON<br />

DRAINS BELOW OVERBOARD DISCHARGE" (GEN SPECS<br />

593a) if applicable.<br />

f. Audible and visual alarms for high and low sewage tank levels wired<br />

to signal in a continuously manned station and in the CHT pump<br />

room (NSTM 593, Section 4.2.5 and GEN SPECS 593a).<br />

3. Ship-Shore Transfer<br />

a. Sewage fuser properly labeled (GEN SPECS 593a).<br />

b. Label plates at each deck discharge connection with warning against<br />

disconnecting sewage hose while it is pressurized, hose hookup/disconnect<br />

procedures and sanitary and health precautions<br />

(GEN SPECS 593a) if applicable.<br />

4. Surveillance<br />

Inspector: Date:________________________<br />

I-3E-15<br />