I-4F-5<br />

COMFLTFORCOMINST 4790.3 REV A CH-1<br />

TABLE 1. SUMMARY OF SIGNIFICANT UNDERWAY TRIAL REQUIREMENTS<br />

Sea Trials Initial Tightness Dive Transit Deep Dive<br />

Policy References Appendix D,<br />

paragraph 2 of this<br />

chapter.<br />

Appendix F,<br />

paragraph 1 of this<br />

chapter.<br />

Appendix F,<br />

paragraph 2 of this<br />

chapter.<br />

Start Depth Surface Surface to 400 ft. Surface to 400 ft.<br />

Conduct Depth Periscope depth or<br />

about 150 ft for SSN<br />

688 Class (155 ft for<br />

SSN 774 Class),<br />

(160 ft for SSN 21<br />

and SSBN/SSGN<br />

726 Class) if sea<br />

state dictates for<br />

trim. Remaining<br />

events of Appendix<br />

D, paragraph 2 of<br />

this chapter no<br />

deeper than 200 ft.<br />

Maximum Keel<br />

Depth<br />

Finish Event Surface from 200 ft<br />

with EMBT blow.*<br />

Surface to 400 ft<br />

but not to exceed<br />

deepest depth<br />

previously escorted<br />

or valve cycling<br />

accomplished.<br />

Additional trials<br />

and testing<br />

permitted within the<br />

Independent Ship<br />

Exercise, crew rest<br />

and other<br />

requirements of this<br />

instruction.<br />

200 ft increments to<br />

one half Maximum<br />

Authorized<br />

Operating Depth,<br />

then 100 ft<br />

increments to<br />

Maximum<br />

Authorized<br />

Operating Depth.<br />

200 ft. One half test depth. Maximum<br />

Authorized<br />

Operating Depth.<br />

Rendezvous with<br />

escort.<br />

Escort Required Yes** No Yes**<br />

Water Depth 400 ft per reference<br />

(p)<br />

Deep dive will be<br />

terminated with an<br />

EMBT blow from<br />

Maximum<br />

Authorized<br />

Operating Depth<br />

Appendix F section<br />

2.<br />

Unlimited. Reference (p).<br />

* May be delayed to permit additional testing, commencing pre-transit valve operating cycling or transit<br />

submerged. However, first surface after initial tightness dive must be by EMBT blow from 200 feet.<br />

** An escort is required on the initial tightness dive and on subsequent first dive to any deeper depths, i.e.,<br />

the first dive to any depth requires an escort. EMBT blow escort requirements given in paragraph<br />

4.4.3.c of this chapter.