APPENDIX G<br />

SUBMARINE SEA TRIAL SITUATION REPORT<br />

(SITREP)<br />

I-4G-1<br />

COMFLTFORCOMINST 4790.3 REV A CH-6<br />

FM USS //<br />

TO COMSUB //N4//<br />

INFO CNO WASHINGTON DC//N77//<br />

COMFLT N43//<br />

COMNAVSEASYSCOM WASHINGTON DC//PMS 392/08O//<br />

DIRSSP WASHINGTON DC//205// {For SSBN/SSGN Only}<br />

// {IF OTHER THAN PARENT TYCOM}<br />

COMSUBDEVRON FIVE SILVERDALE WA//N3//<br />

COMSUBGRU //N5//<br />

COMSUB//<br />

////<br />

(OTHER UNITS IN AREA IF APPLICABLE)//<br />

BT<br />

UNCLAS //N09094//<br />

MSGID/GENADMIN/USS //<br />

SUBJ/(TYPE AVAILABILITY) SITREP (SEQUENTIAL NUMBER)//<br />

REF/A/DOC/COMFLTFORCOM///<br />

REF/B/DOC/AS APPLICABLE///<br />

NARR/ REF A IS COMFLTFORCOMINST 4790.3, <strong>JOINT</strong> <strong>FLEET</strong> <strong>MAINTENANCE</strong> <strong>MANUAL</strong>, VOLUME II.<br />

RMKS/1. CO'S SUMMARY, EVENTS 1-9 COMPLETED WITH THE FOLLOWING DEFICIENCIES NOTED:<br />

A. SUBSAFE/URO DEFICIENCIES.<br />

1) #1 SCOPE HULL GLAND LEAK 1 DPM AT 20% TD<br />

2) TDU VENT, TD-104 LEAKS 3 DPM AT 65% TD.<br />

3) STERN PLANES AUX ANGLE INDICATOR ON BCP DOES NOT ILLUMINATE, URO-16<br />

B. NON-SUBSAFE/URO DEFICIENCIES.<br />

1) SCULLERY DRAIN LEAKING AT FITTING F-18, 27 DPM<br />

2) 3 FLOOR TILES IN CREWS MESS LIFTED AFFECTING SANITATION<br />

3) CO HOT WATER SHOWER RECIRC PUMP FAILED<br />

2. PREVIOUS DEFICIENCIES REPORTED AND STATUS.<br />

(LIST ALL PREVIOUS DEFICIENCIES AND CURRENT STATUS-THE GOAL IS TO CAPTURE THE<br />

COMPLETE MATERIAL CONDITION IN EACH MESSAGE) STATUS = REPAIRED (R), CORRECTIVE<br />

ACTION REQUIRED (CAR), NOT APPLICABLE (NA)<br />

EXAMPLE –<br />

1) SCULLERY DRAIN LEAKING AT FITTING F-18, 27 DPM -R<br />

2) 3 FLOOR TILES IN CREWS MESS LIFTED AFFECTING SANITATION - CAR<br />

3) CO HOT WATER SHOWER RECIRC PUMP FAILED - CAR<br />

4) #1 SCOPE HULL GLAND LEAK 1 DPM AT 20% TD - CAR<br />

5) TDU VENT, TD-104 LEAKS 3 DPM AT 65% TD - CAR<br />

6) STERN PLANES AUX ANGLE INDICATOR ON BCP DOES NOT ILLUMINATE, URO-16 - R<br />

3. ADDITIONAL INFO.<br />

1) DESCRIBE ANY ADDITIONAL INFO DESIRED OR LIST "NONE".<br />

4. TYCOM, NAVSHIPYD, AND NAVSEA REPS CONCUR-DO NOT CONCUR (AS APPROPRIATE).//<br />

BT<br />

NOTE: ENSURE MESSAGES ARE IN ACCORDANCE WITH NTP-3 FORMAT AND CURRENT<br />

PLAIN LANGUAGE ADDRESS DIRECTORY (PLAD) IS UTILIZED.