c. The Consultant shall submit to the Commissioner all original survey field notes.<br />

8. The Utility Profile shall be plotted under the corresponding Plan view.<br />

9. Where the work requires only one sheet, the sheet shall be arranged so that sufficient space is available <strong>for</strong> notes<br />

legend, <strong>and</strong> key plan.<br />

10. The Plan <strong>and</strong> Profile drawings shall show a match line to tie together areas depicted on different sheets.<br />

11. Where more than one sheet is required, the sheets shall be numbered consecutively.<br />

12. All individual locations shall show the North Meridian oriented to top of drawing or to right margin of the drawing.<br />

J. CLEAN BASE PLANS<br />

1. The Consultant shall prepare Clean Base Plans - which shall be graphic representation of the project that is suitable<br />

<strong>for</strong> use as a base plan set <strong>for</strong> the development of Schematic, Preliminary, <strong>and</strong>/or Final Contract Documents.<br />

Graphic elements that shall be shown include mapped right-of-way lines (including lengths, block interior angles <strong>and</strong><br />

ROW widths, Legal Grades), property lines, possession lines, lot lines, Block <strong>and</strong> Lot numbers, house number,<br />

buildings (including number of stories, type <strong>and</strong> usage), ancillary development, street/sidewalk hardware (manhole<br />

covers, poles, etc.), existing curblines <strong>and</strong> edges of pavement, bulkhead <strong>and</strong> pier head lines, limits of wetl<strong>and</strong>s,<br />

easements, trees, theoretical centerline baseline with stationing, <strong>and</strong> north arrow.<br />

2. Text elements shall be limited to street names, stationing, <strong>and</strong> other “NECESSARY” items. Generally, elements to<br />

be excluded include, but are not limited to: elevations, lane lines, redundant text, “condition” text. There shall be no<br />

labeling of walks, grass, etc. The Consultant shall submit a “one-sheeter” sample <strong>for</strong> approval prior to the<br />

development of the Topographic Program. No elevations will be shown on this plan. The base map shall be plotted<br />

on a separate 28”x40” (F) size with a horizontal scale of 1”=30’.<br />

K. TOPOGRAPHICAL PLAN<br />

1. The Topographical Plan(s) shall be plotted by superimposing the Topographic Survey data on to the Clean Base<br />

Plan.<br />

2. Inverts <strong>and</strong> Rim (center of the cover) elevation shall be shown <strong>for</strong> sewers <strong>and</strong> catch basins. All street surface<br />

elevations as described in section C.1 “f” shall be shown. Elevations shall be shown on City owned “irons” only (not<br />

on private utilities). Legal grades shall be shown. Separate spot elevation drawings shall be produced where a full<br />

data plotting would produce a “crowded” presentation - as directed by the City.<br />

3. Topographical Plan(s) limits shall be coincident with the topographic survey limits <strong>and</strong> as herein defined - including<br />

the nearest connected manhole outside the project limits.<br />

4. The Topographical Plan(s) shall be of 28”x40” (F) size, <strong>and</strong> the scale of the drawings shall be 1”=30’. The scale<br />

shall be shown below the Plan view.<br />

L. UTILITY PLAN AND PROFILE<br />

1. The Utility Plan(s) shall be plotted by superimposing the Utility data on the Base Plans excluding all shown<br />

elevations in the Plan view (except <strong>for</strong> Legal Grades, which must be shown both in Plan <strong>and</strong> Profile view).<br />

2. The Utility Profile(s) generally shall include cross sections of all sewer manholes, <strong>and</strong> all sewer pipes which are<br />

shown on the utility plan (excluding those on side streets). In addition, rim <strong>and</strong> invert elevations <strong>for</strong> all shown<br />

manholes, <strong>and</strong> invert elevations, sewer type, size, <strong>and</strong> pipe material <strong>for</strong> all shown sewer pipes must be indicated.<br />

Legal grade <strong>and</strong> roadway center line profiles must also be shown on the utility profile. .<br />

3. Sewer <strong>and</strong> Water utilities shall be identified by approved line type with the following in<strong>for</strong>mation identified: type of<br />

utility, size, configuration, etc.<br />

4. Existing <strong>and</strong>/or “From Record” Sewer <strong>and</strong> Water utility lines shall be indicated <strong>and</strong> plotted to scale with approved<br />

line types.<br />

5. Inverts <strong>and</strong> Rim elevation shall be shown <strong>for</strong> sewers in Profile view only.<br />

6 Profile(s) limits shall be coincident with the topographic survey limits <strong>and</strong> as herein defined.<br />

NYC Department of Design <strong>and</strong> Construction<br />

Infrastructure, October 2012<br />

GR-20