a) General description of all sewers located within the project area;<br />

b) Maps of all existing drainage plans;<br />

c) Maps of existing sewer easements;<br />

d) Maps/sketches of all proposed sewer projects;<br />

e) A discussion of all topographic feature;<br />

f) Proposed mapping or demappings;<br />

g) Outfall locations;<br />

h) Encroachments upon sewer easements, etc.<br />

C. DRAINAGE AND GRADE STUDY, AND DRAINAGE PLAN<br />

1. This study shall provide <strong>for</strong>:<br />

a) The retention of as many of the existing grades <strong>and</strong> as many of the existing street systems as possible, provided<br />

the procedures, concepts <strong>and</strong> criteria used in the <strong>design</strong> of these grades <strong>and</strong> street systems are in accordance with<br />

the <strong>design</strong> parameters of the Department, <strong>and</strong> of the Bureau of Sewers.<br />

b) The retention of as much of the existing sanitary <strong>and</strong> storm water sewer systems(s) as possible, provided the<br />

sewers meet the present <strong>design</strong> criteria of the Bureau of Sewers. The Consultant must consider the age, condition<br />

<strong>and</strong> capacity of the existing sewer system in preparing the proposed drainage plans(s). In order to evaluate all the<br />

factors relating to this decision, the Consultant will be required to consult with the various Divisions of the Department<br />

of Environmental Protection that may have knowledge of the conditions affecting the sewers.<br />

2. In evaluating the feasibility of revising existing drainage plan(s), the Consultant shall endeavor to accommodate the<br />

recommended changes within the mapped street widths <strong>and</strong> easements, <strong>and</strong> legal grade lines of the streets. In instances<br />

where such accommodation proves impractical, the Consultant shall judiciously modify street <strong>design</strong> proposals to enable<br />

the Consultant to produce a workable drainage plan.<br />

3. Prior to commencing the <strong>design</strong> of the proposed drainage plan, the Consultant shall consult with the Drainage Section<br />

of the Department of Environmental Protection on the retention of the existing sewer <strong>and</strong> the proposing of sewers that<br />

slope contrary to the slope of the street, as determined from the final mapped grade.<br />

4. The Consultant is advised that there may be other projects under current or future <strong>contracts</strong> between other<br />

consultants <strong>and</strong> the Department that should be considered in the <strong>design</strong> of this project.<br />

5. When <strong>design</strong>ing the sanitary <strong>and</strong> storm water sewers <strong>for</strong> this project, the tributary flow from adjacent areas, outside<br />

the limits of this project, must be included.<br />

6. Previously completed drainage plans that affect the project area must also be considered.<br />

7. With respect to sanitary sewer schemes, the Consultant shall be required to utilize all existing area interceptor sewers<br />

<strong>for</strong> sanitary sewer drainage.<br />

8. The Design of all Sanitary <strong>and</strong> Storm Water Sewers shown on the proposed drainage plans shall:<br />

a) Be based upon approved adopted final maps where available, <strong>and</strong>/or proposed grades <strong>and</strong> street systems,<br />

or upon otherwise available topographic maps of the area <strong>and</strong> corresponding final <strong>and</strong>/or proposed grades.<br />

b) Be <strong>related</strong> to the prevailing zoning regulations, l<strong>and</strong> occupancy <strong>and</strong> estimated future population with due<br />

allowance <strong>for</strong> practical ultimate need when the areas are fully built up.<br />

c) Be <strong>related</strong> to the probable extent of pervious <strong>and</strong> impervious surface cover when the areas are fully<br />

developed. Underdeveloped residential, industrial, or commercial areas, parks, Government reservations, <strong>and</strong><br />

institutional l<strong>and</strong> shall be treated on an area basis only.<br />

d) Be in con<strong>for</strong>mity with current practices, <strong>requirements</strong> <strong>and</strong> <strong>design</strong> criteria of the Bureau of Water <strong>and</strong> Sewer<br />

Operations.<br />

NYC Department of Design <strong>and</strong> Construction<br />

Infrastructure, October 2012<br />

GR-43