<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>OCD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-TN-09-0008<br />

page 214 of 350<br />

○ Input interface to the AI function for the file based configuration (e.g. data retention<br />

policies, data circulation rules, etc.) provided by the MCC function (e.g. distributed<br />

archived with different data retention policies);<br />

○ Input and output data circulation performed through the DC function;<br />

○ Input and output interface for the PDIs gathering and supply (archival and retrieval)<br />

with the DPC function in support of the <strong>PDGS</strong> processing activities;<br />

○ Output interface for the “archive reports” supply via the DC function to the DAX and the<br />

MPA functions that summarizes archive / removal / update activities of every<br />

distributed archive;<br />

○ Query interface on the archive content for data discovery purposes (e.g. network<br />

interface);<br />

○ Output interface for archived PDIs supply towards the DAG function in support of the<br />

<strong>PDGS</strong> data-access activities;<br />

○ Archived data and metadata configurable import/export interfaces;<br />

○ Input and Output Interfaces to the LTA service function (i.e. systematic circulation to<br />

the LTA service function and on-request data retrieval from the LTA service function);<br />

○ M&C interface for status monitoring;<br />

5.2.3.7 Long-Term Archive (LTA) Service Function<br />

5.2.3.7.1 Function Objectives and High-Level Description<br />

The <strong>PDGS</strong> LTA service is responsible for ensuring long-term data preservation of <strong>Sentinel</strong>-2<br />

data, including product and auxiliary data.<br />

As such, it is in charge of:<br />

○ Archiving the MSI Product Data Items and auxiliary data provided by the AI function<br />

for LTA management;<br />

○ Restoring the MSI Product Data Items and auxiliary data on request to the AI function;<br />

○ Providing bulk data re-processing capabilities on the locally archived dataset.<br />

5.2.3.7.2 Design Drivers and Constraints<br />

The following drivers and constraints are identified:<br />

○ Maximum reuse of European existing infrastructures;<br />

○ Service provider reliability;<br />

5.2.3.7.3 Function Interfaces<br />

The following interfaces are identified for the LTA service:<br />

○ Input interface to receive PDI and auxiliary data from the AI function from remote<br />

centres;<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!