<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>OCD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-TN-09-0008<br />

page 260 of 350<br />

2) The OLQC function according to its configuration and provided product-type to be<br />

checked, verifies autonomously whether product relevant parameter-values and<br />

metadata are within threshold ranges;<br />

3) New generated Quality Indicators are autonomously stored as QI PDIs that might be<br />

included as product metadata according to configuration;<br />

4) The OLQC function autonomously generates a quality report on the verified products<br />

that summarises performed activities such as the quality checks, appended QI<br />

metadata, etc.<br />

6.5 Data Circulation (DC) Operations<br />

6.5.1 PRINCIPLES<br />

6.5.1.1 Data Circulation Concepts<br />

The <strong>PDGS</strong> DC function is responsible for performing file exchange operations between subsystem<br />

interfaces within and external to a <strong>PDGS</strong> centre.<br />

The DC function will support interface electronic and media data circulation according to the<br />

<strong>PDGS</strong> needs. <strong>PDGS</strong> DC function supports different “media” as any physical storage device<br />

pluggable to a computer (e.g. external USB HDDs, LTO equipment, etc). In addition it will be<br />

able to interface with the on-ground EDRS equipment for data multicasting.<br />

Data circulation operations performed either via electronic means or physical media will be<br />

identified and managed according to their nature. Electronic data circulation interfaces will be<br />

characterized by means of typical connectivity parameters such as hostname, protocol used,<br />

username, etc, while physical media interfaces will be identified from the physical media<br />

hardware devices to be circulated.<br />

The DC function allows defining data circulation rules for different type of files to be<br />

performed between two interfaces (source and target interface). It systematically performs<br />

data circulation required operations based on the new data available and the configured data<br />

circulation rules in a systematic manner and data-driven manner.<br />

Circulation activities are systematic and will limit operator intervention to the sole<br />

management of media volumes when required (e.g. load new media for data input, unload<br />

when complete, change media when full, etc). The DC activities will be triggered either:<br />

○ Automatically on availability of new files at an electronic input interface;<br />

○ Manually by the operator on reception of new media (e.g. by post mail)<br />

6.5.1.2 Horizontal Support to other <strong>PDGS</strong> functions<br />

The DC function supports all other <strong>PDGS</strong> functions when require circulating files (file retrieval<br />

and delivery operations) to and from other function interfaces internal or external hosted in<br />

other centres.<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!