29.11.2014 Views

GSC Sentinel-2 PDGS OCD - Emits - ESA

GSC Sentinel-2 PDGS OCD - Emits - ESA

GSC Sentinel-2 PDGS OCD - Emits - ESA

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>OCD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-TN-09-0008<br />

page 100 of 350<br />

Product-<br />

Type<br />

Identifier<br />

Basic Product<br />

Subscriptions<br />

Seasonal Subscriptions<br />

S2MSI0 √ N/A<br />

Optimised Cloud-Free<br />

Subscriptions<br />

N/A<br />

S2MSI1A √ √<br />

S2MSI1B √ √<br />

S2MSI1C √ √ √<br />

Table 4-4 <strong>Sentinel</strong>-2 Data-Set Subscriptions per product-type<br />

4.4.4 PRODUCT QUALITY<br />

User needs in terms of product quality derive from a set of requirements expressed in<br />

<strong>Sentinel</strong>-2 MRD [AD-01]. In order to meet these data quality standards and to ensure data<br />

integrity, the measurement system (including both space and ground sub-systems) shall be<br />

calibrated and the resulting products submitted to a Quality Control (QC).<br />

The following paragraphs present the main quality requirements applicable to the Level-1C<br />

(S2MSI1C) and prototype Level-2A (S2MSI2Ap) products.<br />

To meet the defined quality requirements, the Calibration and Validation (Cal/Val) plan<br />

defined in section 4.5.4.10 will systematically be applied. In complement, the operational<br />

monitoring of the resulting product-quality will be ensured through well-defined QC<br />

procedures.<br />

Products will be annotated with Quality Indicators (QI), which provide to the user the required<br />

information to assess the suitability of the data for a particular use/application. The <strong>Sentinel</strong>-2<br />

Product Definition Document [RD-07] details the QI concept and provides a complete list of<br />

the QIs provided with each product.<br />

4.4.4.1 Level-1C Quality Baseline<br />

Concerning the radiometry requirements, Table 3-2 shows the spectral bands characteristics<br />

and the required Signal-to-Noise Ratio (SNR) for the reference radiances (L ref ) defined for the<br />

mission. Other radiometric image quality requirements are presented in Table 4-5.<br />

Radiometric image quality requirement<br />

Performance<br />

Absolute calibration knowledge accuracy<br />

3 % (goal) , 5 % (threshold)<br />

Cross-band calibration knowledge accuracy 3 %<br />

Multi-temporal calibration knowledge accuracy 1 %<br />

Linearity knowledge accuracy 1 %<br />

Modulation Tranfer Function (MTF)<br />

10m bands: between 0.15 and 0.3<br />

20m and 60m bands: below 0.45<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!