<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>OCD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-TN-09-0008<br />

page 248 of 350<br />

6.1.2 OPERATION SCENARIOS<br />

6.1.2.1 Data Reception Configuration<br />

This scenario accounts for the operator-driven configuration of the DRX function in a CGS<br />

according to the <strong>Sentinel</strong>-2 specific needs.<br />

The following steps are identified for this operation scenario:<br />

1) The configuration of the physical locations in geodetic position and altitude of all X-<br />

Band LEO tracking antennas or Ka-Band GEO pointing antennas enabled for receiving<br />

the <strong>Sentinel</strong>-2 satellites;<br />

2) The ground station and antennas masks configuration is provided to the MCC function.<br />

Such configuration will be later on used by the MPL function for the mission planning<br />

activities (cf. section 6.15);<br />

3) The configuration of the RF signal acquisition, including the downlink frequencies and<br />

signal levels according to the <strong>Sentinel</strong>-2 spacecrafts, possibly differently per <strong>Sentinel</strong>-2<br />

spacecraft;<br />

4) The configuration of the front-end data-handling operations (e.g. the virtual channels<br />

identification);<br />

5) Data archiving configuration including:<br />

o The mapping of VCIDs into the archive files (all packets from the same virtual<br />

channel grouped in a single ordered stream as per data transmission<br />

constraint). The map is done according to the <strong>Sentinel</strong>-2 VCID map per<br />

spacecraft<br />

o Maximum dimension of the archive folder per pass (containing all archived<br />

files). An adequate maximum dimensioning will be needed to preserve the<br />

retrieval performances<br />

o The data retention time in the archive<br />

6) Data distribution configuration, including:<br />

o The front-end processing unit selected for nominal real-time data-supply among<br />

the two hot redundant items;<br />

o The network distribution rules to data consumers for data supply. This will be<br />

configured under the form of a routing table associating sink network addresses<br />

to the source data discriminating S/C-ID, VCID, and APID identifiers e.g.<br />

{netaddr X; enabled; S2A; VC 4; AP-x}.<br />

7) Monitoring and Control reporting configuration, including:<br />

o The list of parameters to be inserted in the reports (e.g. Mission, frames<br />

ingested, RS corrected frames, RS un-correctable frames, carrier input level,<br />

etc.). According to a well-defined ICD, Data reception reports will be customised<br />

for usage by the MPA function for assessment of the data reception<br />

performance<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.