6.5.3.2 Electronic Data Circulation<br />

This scenario describes the autonomous data circulation operations performed electronically<br />

(i.e. network connectivity not involving media usage). The electronic data circulation<br />

operations are performed systematically and automatically. They are triggered by a polling<br />

frequency on the source interface and performed autonomously without any operator<br />

intervention.<br />

The following steps are identified for this operation scenario:<br />

1) The DC function retrieves autonomously from the configured source interface new files<br />

according to the data circulation rules. If required (data circulation post-retrieval file<br />

transformations configuration), file conversions are applied to the new files;<br />

2) The DC function delivers autonomously retrieved files to the configured target interface<br />

according to the data circulation rules. All completed data circulation operations will be<br />

reported (a data circulation report will be generated for the <strong>PDGS</strong>/MPA function).<br />

Some use cases are presented according to this operation scenario:<br />

S2HKTM product data circulation from the PDMC to the FOS;<br />

<strong>Sentinel</strong>-2 products supply for ground link EDRS data circulation. The DC function will<br />

provide to the EDRS ground link gateway products to be circulated making use of<br />

EDRS capabilities;<br />

Between centres data circulation such as the mission reference files circulated from<br />

the applicable interfaces to the Payload Data Management Centre;<br />

Internal data circulation such as the mission reference files circulation in the PDMC<br />

from the MCC function to the RP function.<br />

6.5.3.3 Data Circulation via Media<br />

This scenario describes data circulation operations performed using different media devices<br />

(e.g. LTO, USB HDD, etc.). It will require operator intervention only for the media volumes<br />

management (i.e. media volumes preparation). Nevertheless, the data circulation operations<br />

are performed systematically. They are triggered by new data available in the source<br />

interface and performed autonomously without any operator intervention except for media<br />

volumes handling when required (i.e. media volume full replacement when writing, media<br />

volume already processed replacement when reading). The data circulation involving media<br />

requires presence of the DC function on both sides of the interface.<br />

The following steps are identified for this operation scenario:<br />

1) The operator prepares the interface media volumes (for writing) in the originator DC<br />

function;<br />

2) New files are autonomously gathered from the source interfaces according to the<br />

configured data circulation rules. If required (data circulation post-retrieval file<br />

transformations configuration), file conversions are applied to the applicable files;<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!