Proceedings <strong>of</strong> the National Conference on<br />

Trends and Advances in Mechanical Engineering,<br />

<strong>YMCA</strong> <strong>University</strong> <strong>of</strong> <strong>Science</strong> & <strong>Technology</strong>, Faridabad, Haryana, Oct <strong>19</strong>-<strong>20</strong>, <strong>20</strong>12<br />

temperature below earth. In 17 th century famous French Chemist Lavoisie kept a thermometer 27 m below earth<br />

surface and found that temperature remain constant throughout the year. In 1799 Humboldt found that the<br />

average temperature below the earth surface is 12° C and only variation <strong>of</strong> temperature is 0.04° C. The Royal<br />

Edinburgh Observatory in Scotland started the exact measurement <strong>of</strong> ground temperature in 1838.<br />

Figure 1 Underground temperature from a borehole south <strong>of</strong> Wetzlar [11]<br />

2.1 GSHP Operation Mode<br />

GSHP are used not only for heating but for cooling too. There are typically three modes for operating these<br />

pumps.<br />

Figure.2 Different GSHP Operation Mode<br />

The feasibility <strong>of</strong> direct cooling is there, when space to be cooled is smaller than heating and the environmental<br />

humidity is less. If the condition opposite then heat pump will act as a chiller and extra additional<br />

dehumidification is required.<br />

The efficiency <strong>of</strong> Heat Pump will be measured in terms <strong>of</strong> COP (Coefficient <strong>of</strong> Performance).<br />

For an electric powered compression heat, COP is expressed as<br />

COP= (Useful Heat / Electric Power Input)<br />

2.2 Various GSHP Systems<br />

GSHP can be classified into open and closed systems, and closed systems may further subdivided into horizontal<br />

and vertical systems, the latter being applicable in a situation when the temperature below a certain depth<br />

remains constant and there is a need to install sufficient heat exchange capacity under a confined surface area. In<br />

GSHP system, many type <strong>of</strong> bore hole heat exchanger configuration have been installed, [11]<br />

Out <strong>of</strong> those two basic concepts are<br />