The whole procedure is repeated until the speed step that corresponds to the specified<br />

maximum speed has been measured.<br />

There must not be any “dead gap” between the occupancy sections. That means<br />

the track sections must be located close together. Track section “Centre” must begin<br />

where the other track sections end <strong>and</strong> vice versa.<br />

Please ensure, that the indicator associated with “Centre” is turned off whenever<br />

the engine reverses direction between two runs of the procedure. There are additional<br />

options, with which the run-out <strong>and</strong> the pause between two passes of the<br />

measurement can be adjusted. If indicator “Centre” is not turned off when the engine<br />

reverses direction then increase the run-out or pause, respectively.<br />

It does not matter, though, whether the indicator, that is associated with the track section<br />

where the engine just reverses its direction, is turned on or off, when the direction<br />

is reversed.<br />

Diagram 78: Measuring the Speed Profile with occupancy sensors<br />