tain track section. In Diagram 85 to Diagram 88 you can see an occupancy sensor<br />

turned on <strong>and</strong> off by a passing train. Occupancy sensors are able to report the presence<br />

of a train inside a certain track section even if the train is not moving. Momentary contacts<br />

are triggered by moving trains only. Momentary contacts can be made for instance<br />

by mechanical track contacts, reed contacts or optical sensors. Occupancy sensors are<br />

often based on current sensing in isolated track sections.<br />

Unlike other programs which require occupancy sensors for automatic train control<br />

<strong>TrainController</strong> is also able to control trains if only momentary track contacts are<br />

used. Occupancy sensors are safer, though, because with momentary contacts special<br />

measures against premature release of blocks <strong>and</strong> routes must be taken.<br />

The following diagrams show the behavior of a momentary contact in the different<br />

phases while a train is passing. The position of the momentary contact is marked with a<br />

short vertical line.<br />

128<br />

Diagram 82: Train is approaching the momentary contact – the contact is turned off<br />

Diagram 83: Train is reaching the momentary contact – the contact is triggered