off again, even if the track occupancy detector is still turned on – this is done because<br />

the Forced Reset option is selected. Turning off flagman “timer” is reported to the<br />

flagman “alarm” by the trigger of “alarm”. The flagman “alarm” now checks its condition,<br />

i.e. if the track occupancy detector is still turned on by some inadvertently uncoupled<br />

cars. If this is the case then “alarm” is turned on <strong>and</strong> performs the emergency<br />

operations.<br />

The time period specified as memory of flagman “timer” must be large enough to enable<br />

the longest/slowest train to leave the occupancy detector. Otherwise a false alarm<br />

would be triggered. On the other h<strong>and</strong> the time period must be shorter than the interval<br />

between two successive trains. Otherwise it could happen that the next train has already<br />

turned on the occupancy sensor when the “timer” is turned off.<br />

It is obvious that this mechanism only works if uncoupled cars can be detected by the<br />

track occupancy detector. If necessary, the axles at the end of each train can be made<br />

conductive using an appropriate resistor.<br />

Example: Simple Track Occupancy Detection<br />

The following example demonstrates how a track occupancy detection is made possible<br />

using temporary track sensors.<br />

Diagram 148: Simple Track Occupancy Detection<br />

In addition to the contact indicators, an additional flagman indicator is needed for indication<br />

of occupancy.<br />

• Place or select the contact indicators into the track diagram <strong>and</strong> specify the digital<br />

addresses of the respective track sensors.<br />

• Create a flagman for indication of occupancy.<br />

• Specify both contact indicators as trigger of the flagman using the option Or.<br />

• Set the memory of the flagman to Toggle.<br />