22.10.2013 Views

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Kundendienst<br />

HEIDENHAIN<br />

<strong>DR</strong> JOH~~NNES HEIDENHAIN Gnlb”<br />

0~~3292Traunreut~~(O8669131-0<br />

17.3.2 Logic Diagram<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01 .09.1995<br />

Page 82.2<br />

The logic states of up to 16 operands (M. I, 0, T, C) can be displayed graphically on the screen at the same<br />

time. 1024 PLC scans can be traced.<br />

A table is displayed from which the desired operands can be selected. The control requests the positions of<br />

the table in a dialog. Wrong inputs can be cleared by pressing DEL. It is possible to enter a trigger condition<br />

for each operand. 512 states are traced before and after a trigger event. The following trigger conditions are<br />

possible:<br />

II II<br />

1 +<br />

trace if the operand is a logical “1”<br />

(trigger on positive edge)<br />

trace if the operand is a logical “0”<br />

(trigger on negative edge)<br />

no trigger<br />

If no trigger condition is entered for any of the operands,<br />

the operand states are traced continuously and the last<br />

1024 states are stored.<br />

e.g. 0 I5 1 + trigger on positive edge<br />

1 06 2 + trigger on negative edge<br />

2 M7 --f no trigger<br />

Soft key >START TRACE<<br />

Switch <strong>TNC</strong> to the operating mode MACHINE<br />

(key on VDUi<br />

The trace function is started with START TRACE; END TRACE or a trigger event end the tracing<br />

PCTR blinking:<br />

PCTR on:<br />

PCTR off:<br />

trigger condition has not occurred yet<br />

trigger condition has occurred; write access to buffer memory<br />

buffer memory is full. logic diagram can be called.<br />

Switch to TRACE mode<br />

Soft key >LOGIC DIAGRAM< to call logic diagram