Function MP A B C D E F Input AE-6<br />
No. Bit Entry Value<br />
Feed rate and spindle override 7620 2<br />
Feed rate override if the rapid traverse key<br />
is pressed in the operating mode<br />
"Program Run"<br />
Override in 2% or 1% increments<br />
(if inactive, always 1%)<br />
Feed rate override if the rapid traverse key<br />
and external direction keys are pressed in<br />
the "<strong>Manual</strong>" mode<br />
Override in 0.01% increments with nonlinear<br />
characteristic curve<br />
0 Š Š Š Š - - +0 = override inactive<br />
+1 = override active<br />
1 Š Š I04 I04 - - +0 = 2% steps<br />
+2 = 1% steps<br />
2 Š Š Š Š - - +0 = override inactive<br />
+4 = override active<br />
3 - - 02 02 - - +0 = override inactive<br />
+8 = 0.01% steps<br />
Feed rate and spindle override 7620 - - - - Š Š %1101<br />
Feed rate override function if the rapid<br />
traverse key is pressed in the operating<br />
mode<br />
"Program Run"<br />
Feed override function<br />
• in the MANUAL mode , if the rapid<br />
traverse key and external direction keys<br />
are pressed<br />
• in the HANDWHEEL mode if the rapid<br />
traverse key and the direction key on<br />
the handwheel are pressed.<br />
0 +0 = feed override inactive<br />
+1 = feed override active<br />
2 +0 = feed override inactive<br />
+4 = feed override active<br />
Override, characteristic curve 3 +0 = feed and spindle override in 1% steps<br />
+8 = feed and spindle override in 0.01% steps<br />
and non-linear characteristic line<br />