Code Numbers<br />
123 MACHINE PARAMETER EDITING FOR END USERS (marked by *)<br />
75368 OFFSET ADJUSTMENT<br />
79513 DISPLAY OF VOLTAGE AND TEMPERATURE<br />
86357 REMOVE EDIT/ERASE PROTECTION<br />
95148 MP MODE<br />
105296 COMPENSATION VALUE LIST<br />
531210 RESETTING M 1000 TO M 2000 AND BYTES 0 - 127<br />
620159 DOWNLOADING RUN-IN PROGRAM VIA INTERFACE<br />
807667 PLC MODE<br />
688379 INTERNAL OSCILLOSCOPE<br />
Machine Parameters<br />
The following list contains the machine parameters of all software versions.<br />
Since, however, certain machine parameters are only valid for a certain software version<br />
or from a certain version on, the list contains columns with symbols for differentiation.<br />
Explanation of the Symbols:<br />
‹ = This machine parameter or entry value is valid for all software versions of this control model.<br />
04 = This machine parameter has been introduced with a certain software version<br />
(e.g. 04 means that the MP has been introduced with the software version 04).<br />
I04 = This machine parameter is inactive.<br />
- = This machine parameter is not available with this control model.<br />
Explanation of the Columns:<br />
A = <strong>TNC</strong> <strong>407</strong> with NC software 243 07* -- (without digitizing)<br />
B = <strong>TNC</strong> <strong>415</strong> with NC software 243 05* -- and 259 91* -- (without digitizing)<br />
C = <strong>TNC</strong> <strong>407</strong> with NC software 243 02* -- (with digitizing)<br />
D = <strong>TNC</strong> <strong>415</strong> with NC software 259 96* -- and 259 97* -- (with digitizing)<br />
E = <strong>TNC</strong> <strong>407</strong> with NC software 243 03* --(equivalent to <strong>TNC</strong> <strong>415</strong>B/425 software)<br />
F = <strong>TNC</strong> <strong>415</strong> with NC software 280 58* -- (special software)<br />
AE-6 = entry values for HEIDENHAIN test unit<br />
RH<br />
1.0 <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> Machine Parameters Overview 16.01.95 10.1 1