14.4 Machine Parameters for the Data Interfaces<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.19958<br />

Page 58<br />

The detailed functions of the machine parameters are explained in the <strong>TNC</strong> <strong>Manual</strong> for Machine Tool<br />

Manufacturers and in the information on the data interface FiS232UV24.<br />

In the operating modes ME, FE1 and FE2, the interface parameters are fixed. In the operating modes<br />

EXTI and EXT2, the interface parameters may be determined via machine parameters<br />

All machine parameters for the data interfaces are user parameters, i.e. they can be selected with the<br />

code number 123.<br />

14.4.1 Machine Parameters for the “Standard Interface”<br />

(e.g. for ME 101, printer)<br />

MP for EXTI<br />

5020.0<br />

5030.0<br />

5201 .O<br />

MP for EXT2 Entry Values Function<br />

5020.1 168 7 data bits, transfer stop by DC3, parity bit (even<br />

parity), 1 stop bit<br />

5030.1 0 Standard data interface<br />

5201 .I 3 Control character for end of program = ETX<br />

The data format and the type of transfer stop must be set at the printer according to the values<br />

of MP5020.0 and MP5020.1.<br />

14.4.2 Machine Parameters for “Blockwise Transfer”<br />

(e.g. for FE 401/B, personal computer with HEIDENHAIN data<br />

transfer software)<br />

MP for EXTI MP for EXT2 Entry Values Function<br />

5020.0 5020.1 168 7 data bits, transfer stop by DC3, parity bit (even<br />

parity), 1 stop bit<br />

5030.0 5030.1<br />

12’ Blockwise Transfer<br />

5200.0 5201.1<br />

22’ Control character for program start = STX<br />

5201 .O 5201 .I<br />

32’ Control character for end of program = ETX<br />

5202.0 5202.1<br />

722’ 1. ASCII character for data input = H’l (e.g. H =<br />

NC program in HEIDENHAIN plain language)<br />

5203.0 5203.1 6g21 2. ASCII character for data input = E<br />

5204.0 5204.1 722’ 1. ASCII character for data output = H’l (e.g. H = NC<br />

program in HEIDENHAIN plain language)<br />

5205.0 5205.1 65” 2. ASCII character for data output = A<br />

5206.0 5206.1 12’ ASCII character for start of command block = SOH<br />

5207.0 5207.1 232’ ASCII character for end of command block = ETB<br />

5208.0 5208.1 62’ ASCII character for positive acknowledgement = ACK<br />

5209.0 5209.1 212’ ASCII character for negative acknowledgement = NAK<br />

5210.0 5210.1 421 ASCII character for end of transfer = EOT<br />

1) ASCII characters are only valid for the transfer of NC programs.<br />

2) If these machine parameters are programmed with 0, the standard values apply.