8. Power Supply<br />
8.1 External Power Supply Requirements<br />
The voltages must correspond to the following definitions:<br />
* Voltages up to 36V :. pen-r<br />
8.1 .I Power Supply<br />
31v<br />
20,4v<br />
U<br />
t<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01 .oi1995<br />
Page 32<br />
Voltage Range Max. Current<br />
Power Consumption<br />
DC Average Value Consumption<br />
lower limit 1LE<strong>415</strong>: 1.5A<br />
I approx. 30 W<br />
20.4 .T. LE <strong>407</strong>: 1.3 A<br />
1.8A approx. 6 W<br />
if half of the inputs/outputs if approx. II3 of the inputs/<br />
are active simultaneously outputs are active<br />
simultaneouslv<br />
upper limit 21 A approx. 25 W<br />
31 V :.. * if half of the inputs/outputs if approx. l/3 of the inputs/<br />
sible with t < 100 ms.<br />
are active simultaneously outputs are active<br />
simultaneously<br />
1 WPP<br />
lziLz31,5VPP<br />
8.1.2 PLC Power Supply<br />
t<br />
The NC-part of the LE must not be connected to the<br />
control voltage of the machine tool. It requires its own<br />
external power supply generated separately according<br />
to the German Standard VDE 0551:<br />
24 V DC voltage with a permissible AC component<br />
(ripple voltage) of 1.5 Vpp (recommended filtering<br />
capacitor 10 000 uF / 40 V-1.<br />
The PLC-part (PLC inputs and outputs) of the LE and the PL 400 is operated with a control voltage of 24V<br />
(of the machine tool), generated according to VDE 0550 (German Standard).<br />
Superimposed AC voltage components arising from a non-controlled three-phase bridge connection with a<br />
ripple factor of 5% (see German Standard DIN 40110/10.75, section 1.2) are permissible. Thus, the highest<br />
absolute value for the upper voltage limit is 326V; the smallest absolute value for the lower voltage limit<br />
is 185V.<br />
32,6V<br />
31v<br />
20,4V<br />
18,5V<br />
The 0 V line of the PLC power supply must be<br />
connected to the central signal ground of the<br />
machine tool (ground line 0 t 6 mm?