Kundendienst<br />

HEIDENHAIN<br />

<strong>DR</strong> <strong>JOHANNES</strong> HEIDENHAIN GmbH<br />

D-83292Traunreut-~(086691 31-O<br />

8. Power Supply<br />

8.1 External Power Supply Requirements<br />

The voltages must correspond to the following definitions:<br />

* Voltages up to 36V :. pen-r<br />

8.1 .I Power Supply<br />

31v<br />

20,4v<br />

U<br />

t<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01 .oi1995<br />

Page 32<br />

Voltage Range Max. Current<br />

Power Consumption<br />

DC Average Value Consumption<br />

lower limit 1LE<strong>415</strong>: 1.5A<br />

I approx. 30 W<br />

20.4 .T. LE <strong>407</strong>: 1.3 A<br />

1.8A approx. 6 W<br />

if half of the inputs/outputs if approx. II3 of the inputs/<br />

are active simultaneously outputs are active<br />

simultaneouslv<br />

upper limit 21 A approx. 25 W<br />

31 V :.. * if half of the inputs/outputs if approx. l/3 of the inputs/<br />

sible with t < 100 ms.<br />

are active simultaneously outputs are active<br />

simultaneously<br />

1 WPP<br />

lziLz31,5VPP<br />

8.1.2 PLC Power Supply<br />

t<br />

The NC-part of the LE must not be connected to the<br />

control voltage of the machine tool. It requires its own<br />

external power supply generated separately according<br />

to the German Standard VDE 0551:<br />

24 V DC voltage with a permissible AC component<br />

(ripple voltage) of 1.5 Vpp (recommended filtering<br />

capacitor 10 000 uF / 40 V-1.<br />

The PLC-part (PLC inputs and outputs) of the LE and the PL 400 is operated with a control voltage of 24V<br />

(of the machine tool), generated according to VDE 0550 (German Standard).<br />

Superimposed AC voltage components arising from a non-controlled three-phase bridge connection with a<br />

ripple factor of 5% (see German Standard DIN 40110/10.75, section 1.2) are permissible. Thus, the highest<br />

absolute value for the upper voltage limit is 326V; the smallest absolute value for the lower voltage limit<br />

is 185V.<br />

32,6V<br />

31v<br />

20,4V<br />

18,5V<br />

The 0 V line of the PLC power supply must be<br />

connected to the central signal ground of the<br />

machine tool (ground line 0 t 6 mm?