Kundendienst<br />
HEIDENHAIN<br />
<strong>DR</strong> <strong>JOHANNES</strong> HElDENHAlN GrnbH<br />
D~83292T~~"aunreut-~.(O8669)31-0<br />
11. Encoders<br />
11.1 Error Messages<br />
Y= A: Signal amplitude too low<br />
B: Frequency exceeded<br />
C: Wrong reference mark spacing<br />
x= CPU number 1 = Main processor<br />
2 = Geometry processor<br />
3 = CLP processor<br />
11.2 Error Causes<br />
Glass scale contaminated or defective<br />
Scanning head contaminated or defective<br />
Cable damaged<br />
- Encoder input of the logic unit ILE) defective<br />
11.3 Checking the Encoders<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.1995<br />
Page 49<br />
In order to determine whether the encoder or the encoder input of the logic unit is defective, the encoders can<br />
be switched at the logic unit For this purpose, the corresponding machine parameters must be altered as well.<br />
Allocation of the axes<br />
to the encoder inputs<br />
X 110.0 o= Xl<br />
Y 110.1 I= x2<br />
Z 110.2 2= x3<br />
IV 110.3 3= x4<br />
V 110.4 4= x5<br />
5= X6*<br />
* X6 may only be used for a machine tool axis, if no spindle orientation is required.<br />
Proceeding if an error message is displayed<br />
- Switch off main switch.<br />
Switch encoder X-axis with e.g. encoder Y-axis at the logic unit.<br />
Switch on main switch.<br />
If the error message POWER INTERRUPTED is generated, call the machine parameters with the code<br />
number 95148 and switch the entry values of the machine parameters 110.0 and 110.1.<br />
Exit the machine parameters and switch on the machine as usual.<br />
If the same error message POWER INTERRUPTED is generated again, the error is located in the encoder or<br />
in the extension cable. If the error message now says “Y” instead of “x”, the encoder input of the logic unit is<br />
defective.<br />
1