Kundendienst<br />

HEIDENHAIN<br />

<strong>DR</strong> <strong>JOHANNES</strong> HElDENHAlN GrnbH<br />

D~83292T~~"aunreut-~.(O8669)31-0<br />

11. Encoders<br />

11.1 Error Messages<br />

Y= A: Signal amplitude too low<br />

B: Frequency exceeded<br />

C: Wrong reference mark spacing<br />

x= CPU number 1 = Main processor<br />

2 = Geometry processor<br />

3 = CLP processor<br />

11.2 Error Causes<br />

Glass scale contaminated or defective<br />

Scanning head contaminated or defective<br />

Cable damaged<br />

- Encoder input of the logic unit ILE) defective<br />

11.3 Checking the Encoders<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 49<br />

In order to determine whether the encoder or the encoder input of the logic unit is defective, the encoders can<br />

be switched at the logic unit For this purpose, the corresponding machine parameters must be altered as well.<br />

Allocation of the axes<br />

to the encoder inputs<br />

X 110.0 o= Xl<br />

Y 110.1 I= x2<br />

Z 110.2 2= x3<br />

IV 110.3 3= x4<br />

V 110.4 4= x5<br />

5= X6*<br />

* X6 may only be used for a machine tool axis, if no spindle orientation is required.<br />

Proceeding if an error message is displayed<br />

- Switch off main switch.<br />

Switch encoder X-axis with e.g. encoder Y-axis at the logic unit.<br />

Switch on main switch.<br />

If the error message POWER INTERRUPTED is generated, call the machine parameters with the code<br />

number 95148 and switch the entry values of the machine parameters 110.0 and 110.1.<br />

Exit the machine parameters and switch on the machine as usual.<br />

If the same error message POWER INTERRUPTED is generated again, the error is located in the encoder or<br />

in the extension cable. If the error message now says “Y” instead of “x”, the encoder input of the logic unit is<br />

defective.<br />