Adaptation of the Data Interface<br />

Function MP A B C D E F Input AE-6<br />

No. Bit Entry Value<br />

Inhibiting a data interface 5000 0 = no interface inhibited<br />

1 = RS-232 inhibited<br />

0<br />

2 = RS-422 inhibited<br />

Control characters for<br />

"Blockwise Transfer"<br />

0 to 32 382 515<br />

Character for beginning and end of program;<br />

the character of end of program is<br />

also valid for the standard data interface<br />

5010.0* I05 I08 - - - -<br />

ASCII character for data input 5010.1* I05 I08 - - - - 0 to 32 382 0<br />

ASCII character for data output 5010.2* I05 I08 - - - - 0 to 32 382 0<br />

ASCII character for beginning<br />

and end of command block<br />

ASCII character for pos. and neg.<br />

acknowledgement<br />

ASCII character for end of data<br />

transfer<br />

* accessible via code number 123<br />

5010.3* I05 I08 - - - - 0 to 32 382 0<br />

5010.4* I05 I08 - - - - 0 to 32 382 0<br />

5010.5* I05 I08 - - - - 0 to 32 382 0<br />

RH<br />

1.0 <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> Machine Parameters MP 5000 - MP 5010.5 08.05.95 10.2 30