Adaptation of the Data Interface<br />
Function MP A B C D E F Input AE-6<br />
No. Bit Entry Value<br />
Inhibiting a data interface 5000 0 = no interface inhibited<br />
1 = RS-232 inhibited<br />
0<br />
2 = RS-422 inhibited<br />
Control characters for<br />
"Blockwise Transfer"<br />
0 to 32 382 515<br />
Character for beginning and end of program;<br />
the character of end of program is<br />
also valid for the standard data interface<br />
5010.0* I05 I08 - - - -<br />
ASCII character for data input 5010.1* I05 I08 - - - - 0 to 32 382 0<br />
ASCII character for data output 5010.2* I05 I08 - - - - 0 to 32 382 0<br />
ASCII character for beginning<br />
and end of command block<br />
ASCII character for pos. and neg.<br />
acknowledgement<br />
ASCII character for end of data<br />
transfer<br />
* accessible via code number 123<br />
5010.3* I05 I08 - - - - 0 to 32 382 0<br />
5010.4* I05 I08 - - - - 0 to 32 382 0<br />
5010.5* I05 I08 - - - - 0 to 32 382 0<br />
RH<br />
1.0 <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> Machine Parameters MP 5000 - MP 5010.5 08.05.95 10.2 30