Kundendienst<br />
HEDENHAIN<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.19958<br />
Page 56<br />
14.3 Connecting Cables and Adaptors for the RS 232C Interface<br />
14.3.1 Wiring Diagram and Adaptor of the RS 232C Interface<br />
X2,, Cable RS232 i LE RS 232 Adaptor Block<br />
LE <strong>407</strong>/<strong>415</strong> Id.No. 239 760 _. Id.No. 239 758 01<br />
LJ 8<br />
DTR 6<br />
SIGNAL GND 7<br />
DSR 20<br />
Signal Designations:<br />
TX0 Transmit Data<br />
RXD Receive Data<br />
RTS Request to Send<br />
CTS Clear to Send<br />
DSR Data Set Ready<br />
DTR Terminal Ready<br />
Data Transfer Cable<br />
Id.No. 242 869 01<br />
FE 401/B<br />
ME 101<br />
In general simplified wiring of the<br />
data transfer cable is sufficient<br />
for the transfer via the RS 232C<br />
interface with DCl/DC3 protocol.<br />
CHASSIS GND<br />
lx0<br />
RX0<br />
RTS<br />
CTS<br />
DSR<br />
SIGNAL GND<br />
The data lines and the control lines of the cable between the LE <strong>407</strong>/<strong>415</strong> and the RS 232C adaptor block<br />
(Id.No. 239 760 ..) are transposed. The pin layout at the connector X21 of the LE <strong>407</strong>/<strong>415</strong> corresponds that<br />
of a data circuit terminating equipment (DCE). Due to the transposed data lines and control lines in the cable<br />
between the LE <strong>407</strong>/<strong>415</strong> and the RS 232C adaptor the allocation at the RS 232C adaptor corresponds to a<br />
data terminal equipment (DTE). Thus, the external units may be connected to the RS 232C adaptor via the<br />
standard HEIDENHAIN data transfer cable (Id.No. 242 869 01).<br />
The RS 232C data interface has different pin assignments at the logic unit X21 and at the<br />
RS 232C adaptor block.<br />
DTR