Kundendienst<br />

HEDENHAIN<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.19958<br />

Page 56<br />

14.3 Connecting Cables and Adaptors for the RS 232C Interface<br />

14.3.1 Wiring Diagram and Adaptor of the RS 232C Interface<br />

X2,, Cable RS232 i LE RS 232 Adaptor Block<br />

LE <strong>407</strong>/<strong>415</strong> Id.No. 239 760 _. Id.No. 239 758 01<br />

LJ 8<br />

DTR 6<br />

SIGNAL GND 7<br />

DSR 20<br />

Signal Designations:<br />

TX0 Transmit Data<br />

RXD Receive Data<br />

RTS Request to Send<br />

CTS Clear to Send<br />

DSR Data Set Ready<br />

DTR Terminal Ready<br />

Data Transfer Cable<br />

Id.No. 242 869 01<br />

FE 401/B<br />

ME 101<br />

In general simplified wiring of the<br />

data transfer cable is sufficient<br />

for the transfer via the RS 232C<br />

interface with DCl/DC3 protocol.<br />

CHASSIS GND<br />

lx0<br />

RX0<br />

RTS<br />

CTS<br />

DSR<br />

SIGNAL GND<br />

The data lines and the control lines of the cable between the LE <strong>407</strong>/<strong>415</strong> and the RS 232C adaptor block<br />

(Id.No. 239 760 ..) are transposed. The pin layout at the connector X21 of the LE <strong>407</strong>/<strong>415</strong> corresponds that<br />

of a data circuit terminating equipment (DCE). Due to the transposed data lines and control lines in the cable<br />

between the LE <strong>407</strong>/<strong>415</strong> and the RS 232C adaptor the allocation at the RS 232C adaptor corresponds to a<br />

data terminal equipment (DTE). Thus, the external units may be connected to the RS 232C adaptor via the<br />

standard HEIDENHAIN data transfer cable (Id.No. 242 869 01).<br />

The RS 232C data interface has different pin assignments at the logic unit X21 and at the<br />

RS 232C adaptor block.<br />