D~83292Traunieut.~(O8669) 31-O<br />
RANGE EXCEEDED<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
01.09.1995<br />
Page 53.1<br />
The range has been exceeded during scanning, i.e. a part of the 3D-contour is outside<br />
the range.<br />
CYCL-PARAMETER INCORRECT 1<br />
The programmed travel or the distance between lines or points is negative or larger<br />
than 56 535 mm (only possible via Q-parameter programming)<br />
TOUCH POINT INACCESSIBLE<br />
The stylus was deflected before the range was reached during approach.<br />
- In the cycle CONTOUR LINES, the stylus was not deflected within the probing range.<br />
STYLUS ALREADY IN CONTACT<br />
The stylus is not at rest, although it is not touching the contour,<br />
PLANE WRONGLY DEFINED I<br />
One of the coordinates of the starting point in the cycle CONTOUR LINES is identical<br />
with the touch probe axis.<br />
START POSITION INCORRECT<br />
- The starting point coordinate that is identical to the starting probe axis, is beyond the range<br />
AXIS DOUBLE PROGRAMMED<br />
The same axis has been programmed for both starting point coordinates in the cycle<br />
CONTOUR LINES.<br />
TIME LIMIT EXCEEDED<br />
In the scanning cycle CONTOUR LINES the first point of the scanned line was not reached<br />
within the programmed time limit.