Kundendienst<br />

HElDENHAlN<br />

11.3.1 Electrical Check of Encoders<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 50<br />

In order go give a precise statement on the electrical function of an encoder, it must be measured with a phase<br />

angle measuring unit (PWM), an oscilloscope and an impedance tester. (see operating instructions Encoder<br />

Diagnostic Kit)<br />

If no phase angle measuring unit is available, the electrical state of the cable, the lamp and the photocells of<br />

an encoder can be checked with an ohmmeter. The following resistances must be measured at the connector<br />

of the encoder:<br />

Encoder connector housing against machine housing (external shield) R