Kundendienst<br />
HEIDENHAIN<br />
<strong>DR</strong><strong>JOHANNES</strong> HElDENHAlN Gmb4-l<br />
D-83292 Traunreur. TB (cl86 59) 31-o<br />
e) Loosen/remove the fixing screws<br />
Remove<br />
knurled screw<br />
Loosen fixing screws<br />
Remow I<br />
knurled screw<br />
f) Lift out the PLC and graphics board.<br />
Insert the new board.<br />
19.5.3 Mounting the PLC and Graphics Board<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.1995<br />
Page 100<br />
68820 E KU607711<br />
The PLC and graphics board is mounted in the reverse order that is was dismounted,<br />
a) Insert and secure the CLP board.<br />
b) Engage the connectors.<br />
Observe that no connectors are switched!<br />
c) Close the logic unit and close the lock.<br />
d) Switch on the main switch.<br />
e) Offset adjustment with code number (see section 16.5).<br />
Exchange is now finished.<br />
\<br />
Loosen<br />
fixing screws<br />
/<br />
NOTE:<br />
Send and store the boards only in the original packaging that protects them from acquiring<br />
static charge. Never use conventional plastics to wrap the boards in.