Kundendienst<br />

HEIDENHAIN<br />

<strong>DR</strong> JoH*NNES HElDErd”*,N GnlbH<br />

DXi3292Traunreut .S?‘1086691 31-O<br />

19.9 Exchanging EPROMs<br />

19.9.1 MOS Protection<br />

For the exchange of EPROMs MOS-protection is indispensable, as otherwise<br />

the EPROMs could be destroyed by static charge. Moreover, all data should be<br />

backed up (see section 15.1).<br />

Observe the mark on the EPROMs (do not turn them by 180”); be sure not<br />

to damage any components during the exchange. Use an appropriate tool.<br />

After the software exchange, the logic unit must be marked with the new<br />

NC-software number (see section 14.1). The offset adjustment with code<br />

number should be performed as well (see section 16.5).<br />

19.9.1 EPROM Designation<br />

Basic Id.No. Location No. (e.g. IC-PI)<br />

\ I<br />

Processor Board <strong>TNC</strong> <strong>415</strong><br />

CLP Board <strong>TNC</strong> <strong>415</strong><br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Index (software version)<br />

Issue: 01 .09.1995<br />

Page 107<br />

e.g. IC drawing punch<br />

and insertion tool<br />

Processor Board <strong>TNC</strong> <strong>407</strong><br />

PLC-EPROM