Kundendienti<br />

15.2 Overview of All Files in RAM<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 65<br />

File File Extension File Selection<br />

Directly via Code Number<br />

NC programs HEIDENHAIN language .H x<br />

NC programs IS0 .I x<br />

Tool files .T x<br />

Pallet tables .P x<br />

Datum tables .D x<br />

Text files .A x<br />

Machine parameters .MP x<br />

Compensation value list .KOR x<br />

PLC program .PLC x<br />

Error messages 1. language .ERl x<br />

Error messages English .ERE x<br />

Dialogs 1. language .DIl x<br />

Dialogs English .DIE x<br />

Text files .A x<br />

Additional information on the files and programs is provided by letters in the status field:<br />

E: The file/program has been selected in the PROGRAMMING mode.<br />

S: The file/program has been selected and activated in the TEST RUN mode.<br />

M: The file/program has been selected and activated in either PROGRAM RUN/ FULL SEQUENCE<br />

or in PROGRAM RUN/SINGLE BLOCK.<br />

P: The file/program is protected against erasing and editing.<br />

IN:The file/program was programmed in Inch.<br />

W:The file/program was not completely transferred to the external memory and thus is no longer<br />

available.<br />

15.3 External Data Output<br />

Connect the external data medium (ME, FE or other peripheral unit, e.g. personal computer with<br />

HEIDENHAIN data transfer software) to the <strong>TNC</strong>.<br />

Prepare the external data medium for data transfer:<br />

press m , and a at the ME<br />

press m at the FE.<br />

Select the operating mode, the Baud rate and the interface assignment (see sections 14.1<br />

and 14.2) at the <strong>TNC</strong>.<br />

The ME (Magnetic Tape Unit) is not very suitable as an external data medium,<br />

as only one file can be stored on one side of a cassette.