Kundendienti<br />
15.2 Overview of All Files in RAM<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.1995<br />
Page 65<br />
File File Extension File Selection<br />
Directly via Code Number<br />
NC programs HEIDENHAIN language .H x<br />
NC programs IS0 .I x<br />
Tool files .T x<br />
Pallet tables .P x<br />
Datum tables .D x<br />
Text files .A x<br />
Machine parameters .MP x<br />
Compensation value list .KOR x<br />
PLC program .PLC x<br />
Error messages 1. language .ERl x<br />
Error messages English .ERE x<br />
Dialogs 1. language .DIl x<br />
Dialogs English .DIE x<br />
Text files .A x<br />
Additional information on the files and programs is provided by letters in the status field:<br />
E: The file/program has been selected in the PROGRAMMING mode.<br />
S: The file/program has been selected and activated in the TEST RUN mode.<br />
M: The file/program has been selected and activated in either PROGRAM RUN/ FULL SEQUENCE<br />
or in PROGRAM RUN/SINGLE BLOCK.<br />
P: The file/program is protected against erasing and editing.<br />
IN:The file/program was programmed in Inch.<br />
W:The file/program was not completely transferred to the external memory and thus is no longer<br />
available.<br />
15.3 External Data Output<br />
Connect the external data medium (ME, FE or other peripheral unit, e.g. personal computer with<br />
HEIDENHAIN data transfer software) to the <strong>TNC</strong>.<br />
Prepare the external data medium for data transfer:<br />
press m , and a at the ME<br />
press m at the FE.<br />
Select the operating mode, the Baud rate and the interface assignment (see sections 14.1<br />
and 14.2) at the <strong>TNC</strong>.<br />
The ME (Magnetic Tape Unit) is not very suitable as an external data medium,<br />
as only one file can be stored on one side of a cassette.