14.5.2 Error Messages at the ME<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

01.09.1995<br />

Page 60<br />

In the ME the electronics is tested, and the external operating conditions are checked. If an error is<br />

detected, the lamps of the operating mode display start blinking. In the following table the error types<br />

are listed:<br />

0 LED off * LED blinking<br />

Indicator Lamp 1 Error Message<br />

0004<br />

0000<br />

oo*o<br />

0000<br />

oo**<br />

0000<br />

o*oo<br />

0000<br />

o*o*<br />

0000<br />

o**o<br />

0000<br />

4404<br />

0000<br />

4444<br />

0000<br />

0+**<br />

0000<br />

Faulty data during transfer<br />

No cassette inserted<br />

Write-enable plug in cassette missing<br />

Wrong operating mode selected<br />

Data of magnetic tape faulty<br />

Magnetic tape blank<br />

Errors in ME electronics<br />

End of tape<br />

Peripheral unit not connected<br />

***0 Data transfer between <strong>TNC</strong> and ME/peripheral unit was interrupted with RI<br />

0000<br />

By pressing ’ the error messages can be cleared.<br />