19.1.5 Determining Data for the Auxiliary Operating Modes:<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.1995<br />
Page 91<br />
If the processor board assembly or the complete logic unit are to be exchanged, or if a software exchange<br />
is to be carried out, the preset values and the current entry values of the auxiliary operating modes should<br />
be determined, so that they can be re-entered after the exchange.<br />
Switch off and on the main switch of the machine tool<br />
1 <strong>TNC</strong> Dialog Display<br />
MEMORY TEST<br />
POWER INTERRUPTED<br />
RELAY EXT. DC VOLTAGE MISSING<br />
MANUAL OPERATING MODE<br />
TRAVERSE REF. POINT .AXlS<br />
.AXIS<br />
.AXIS<br />
POSITION DISPLAY (upper row)<br />
0 0 0 0 0<br />
ACTL REF LAG NOML DIST<br />
POSITION DISPLAY (lower row)<br />
0 0 0 0 0<br />
ACTL REF LAG NOML DIST<br />
The lower position display can be switched on<br />
with the soft key >STATUS ON< (only with<br />
split screen).<br />
CHANGE MM/INCH<br />
0 0<br />
MM INCH<br />
PROGRAM ENTRY<br />
0 0<br />
HEIDENHAIN IS0<br />
-1MI T X-<br />
_lMITX+<br />
LIMIT Y-<br />
/ )<br />
i /<br />
_12,<br />
LIMIT Y+ __ ~ I.<br />
Soft key<br />
,kxlS LIMIT<<br />
;witch on control voltage<br />
>o not yet traverse the reference points!<br />
dote down the current setting for the position<br />
lisolav the switch to ACTL bv oressina<br />
Aark unit with a cross<br />
dark type of program<br />
dote down the limit values<br />
Do not forget the algebraic sign!)<br />
f MP7490 = 1, three different limits may be<br />
Ictive. In this case note down all 3 values.