Kundendienst<br />

16.3 Switching Over the Position Display<br />

16.4 Feed Adjustment<br />

Function<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 76<br />

Switch <strong>TNC</strong> to operating mode MACHINE<br />

Prepare <strong>TNC</strong> to be switched over to position display<br />

Press ENT to switch to desired position display<br />

(DIST, ACTL, REF. LAG, NOMLi<br />

Press soft key >END< to switch the <strong>TNC</strong> to the<br />

operating mode EDITING<br />

Check/adjust the machine parameters. (Note down the original values before changing.)<br />

MP Entry Function Original Value<br />

ValLU3<br />

1390 0<br />

Feed precontrol ON<br />

in the automatic operating modes<br />

7290 0 Display step = 1 pm<br />

Switch the position display to LAG (display of servo lag).<br />

Enter the following test program:<br />

e.g. 1 LBL 1<br />

2x100 RO F29999 M (select a larger traverse range if possible)<br />

3x0 R F M<br />

4 CALL LBL 1 REP 10<br />

Run the test program in the operating mode PROGRAM RUN/FULL SEQUENCE.<br />

Adjust the feed at the servo amplifier (tachometer) until the servo lag display is approx. zero for<br />

positioning in both directions.<br />

Repeat adjustment for all axes.<br />

Reset the machine parameters and the position display to the original values.<br />

i