Kundendienst<br />
19.<br />
19.1<br />
19.1.1<br />
HEDENHAIN<br />
<strong>DR</strong> JOHPINNES HElDENHAlN GnlbH<br />
D~d3292Tra”nre”t. ?,S,O8669, 31-O<br />
Exchange Instructions<br />
General Remarks<br />
Equipment Required<br />
I external data medium, e.g. FE 401/B or personal computer with connecting cable<br />
1 tool set (screwdriver, socket wrench etc.)<br />
1 MOS protection device (only required for exchanging boards or EPROMs)<br />
19.12 MOS Protection<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
Issue: 01.09.1995<br />
Page89<br />
If the processor board, the PLC and graphics board, the CLP boards or EPROMs are to be exchanged, a MOS<br />
protection is definitely required, as otherwise MOS components on the boards or EPROMs may be destroyed.<br />
Note:<br />
Avoid any unprotected handling or contact of the boards or EPROMs with statically charged objects<br />
(packaging material, storage etc.).<br />
MOS Protection<br />
Bracelet<br />
o/<br />
19.13 Software Compatibility<br />
Potential compensating line<br />
with protective resisitor<br />
mat lays on the machine table<br />
Exchange units (complete logic unit) are generally supplied with the latest software version. Exchange boards<br />
however, are always supplied without software and without software protection module.<br />
For this reason, the EPROMs and the software enable module of the defective board must be inserted into<br />
the exchange board at site (see sec. 19.9). Before sending us exchange boards for repair, always remove the<br />
EPROMs and the software enable module.