Kundendienst<br />
HEIDENHAIN<br />
14.5.5 Error Messages during Data Transfer<br />
1 TRANSFERRED VALUE ERRONEOUS X<br />
x= A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
K<br />
L<br />
faulty character frame<br />
character overflow<br />
character frame or character overflow<br />
parity error<br />
character frame or parity error<br />
character overflow or parity error<br />
character frame or parity error<br />
receiving-buffer overflow<br />
1.Incorrect ESC sequence (only in ME-mode)<br />
TRANSFERRED DATA INCORRECT X<br />
SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />
01.09.1995<br />
Paqe 62.1<br />
x= A character frame faulty<br />
D parity error<br />
M control has received the character for “negative acknowledgement” (NAK)<br />
more than 3 times<br />
N control has sent the character for “negative acknowledgement” (NAK) more<br />
than 3 times<br />
BAUD RATE NOT POSSIBLE<br />
If both data interfaces are activated simultaneously (RS 232 / RS 422). the baud rates of both<br />
interfaces must be the same.<br />
INTERFACE ALREADY ASSIGNED<br />
A data interface cannot be used for two operating modes simultaneously (e.g. DNC-mode and<br />
programming at the same time is not possible with one data interface).<br />
EXT. IN-/OUTPUT NOT READY<br />
DSR signal at the <strong>TNC</strong> missing<br />
Defective or wrong transfer cable<br />
Wrong interface assignment<br />
PROGRAM INCOMPLETE<br />
Data transfer was interrupted before the program was completely loaded