3D-Touch Probe (General Parameters)<br />

Function MP A B C D E F Input AE-6<br />

No. Bit Entry Value<br />

Selection of touch trigger probe 6010* Š Š Š Š Š Š 0 = transmission via cable (TS 120)<br />

1 = infrared transmission (TS 510)<br />

Probing feed rate 6120* Š Š Š Š Š Š 10 to 3 000 [mm/min] 80<br />

Maximum measuring range 6130* Š Š 04 04 Š Š 0.001 to 99 999.9999 [mm] 1<br />

Safety clearance over measuring<br />

point for automatic measurement<br />

6140* Š Š Š Š Š Š 0.001 to 99 999.9999 [mm] 1<br />

Rapid traverse for probe cycle 6150* Š Š Š Š Š Š 10 to 10 000 [mm/min] 2000<br />

M-function for rotating the<br />

spindle by 180° to compensate the<br />

center misalignment of the stylus<br />

* accessible via code number 123<br />

6160* - - - - Š Š -1 = oriented spindle stop via NC<br />

0 = function inactive<br />

1 to 88 = number of M-function for oriented<br />

spindle stop via PLC<br />

RH<br />

1.0 <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> Machine Parameters MP 6010 - MP 6160 08.05.95 10.2 34<br />