HEIDENHAIN<br />

<strong>DR</strong> .<strong>JOHANNES</strong> HEIDENHAIN GnlbH<br />

D~~3292TIEiunre"t-~(08669)31-0 SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

01.09.1995<br />

Kundendienst Page 59<br />

14.5. Error Messages<br />

14.5.1 Error Messages at the <strong>TNC</strong> in the ME-Mode<br />

WRONG OPERATING MODE<br />

- The wrong operating mode no operating mode was selected on the external data medium<br />

r---<br />

WRONG PROGRAM DATA<br />

Wrong program data have been detected during data transfer. The control attempted<br />

three times to read the data from the magnetic tape before interrupting the process.<br />

DATA MEDIUM MISSING<br />

No cassette has been inserted into the drive.<br />

DATA MEDIUM EMPTY<br />

No programs are stored on the data medium (cassette).<br />

DATA MEDIUM WRITE-PROTECTED 1<br />

The write-enable plug on the cassette is missing<br />

I PROGRAM INCOMPLETE I<br />

- Data transfer was interrupted before the program was transferred completely.<br />

EXT. INPUT/OUTPUT NOT READY<br />

The DSR-signal is missing at the <strong>TNC</strong>.<br />

ME not connected<br />

- Defective or wrong transfer cable<br />

Wrong interface assignment<br />

ME: TAPE END<br />

The cassette is full. To continue data transfer, turn over or exchange the cassette.