F!!! HEIDENHAIN<br />

14. Data Interfaces<br />

14.1 Operating Modes<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.19958<br />

Page 54<br />

For data transfer the <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> can be switched to the following 5 interface operating modes:<br />

ME<br />

EXTI<br />

F EXT2<br />

For connection of the HEIDENHAIN Magnetic Tape Unit ME 101/102 or other peripheral units<br />

(e.g. printer); data transfer in standard data format; data format (7 data bits, 1 stop bit, even parity)<br />

and Baud rate (2400 bdi adapted to the ME.<br />

For connection of the HEIDENHAIN Floppy Disk Unit FE 401 or other peripheral units (e.g.<br />

personal computer with HEIDENHAIN data transfer software). Data are transferred with a special<br />

protocol (blockwise transfer) for data security. Data format 17 data bits, 1 stop bit, even parity) and<br />

the transfer protocol are adapted to the FE 401. In the interface mode FE 2 the file names must<br />

be noted down for output of machine parameters, compensation value lists and PLC-programs,<br />

as the directory of the external data medium cannot be displayed by the <strong>TNC</strong> and the file name<br />

is needed again for data input.<br />

n If the floppy disk unit FE 401 is used as an external data medium, no letters are permitted<br />

in program names.<br />

When using the FE 401 the Baud rate at the control must be set to 9600<br />

For connection of the HEIDENHAIN Floppy Disk Unit FE 4018 (or FE 401, software version<br />

230 626 03 and later) or other peripheral units. Data are transferred with a special protocol<br />

(blockwise transfer) for data security. Data format (7 data bits, 1 stop bit, even parity) and the<br />

transfer protocol are adapted to the FE 401/B. The disk directory is automatically displayed by<br />

the <strong>TNC</strong> (ESC sequence).<br />

All characters are permitted for program names.<br />

The Baud rate set at the <strong>TNC</strong> must always match that of the FE 410/B.<br />

Possible Baud rates are 2400, 4800, 9600, 19 200 and 38 400.<br />

To adapt the transfer of data to external units in standard data format and for blockwise transfer.<br />

The interfaces for data transfer are adapted via machine parameters.<br />

Any Baud rate may be selected.<br />

Peripheral units for the EXT operating mode are:<br />

Tape punching units and punched tape readers<br />

Printers or matrix printers for graphic printouts<br />

Mass storage media or programming stations for “Blockwise Transfer”<br />

Programming stations and personal computers for external programming<br />

The Baud rate set at the <strong>TNC</strong> must always match that of the peripheral unit.<br />

Possible Baud rates: 1 IO to 38 400.