HEIDENHAIN<br />

<strong>DR</strong> JOHPINNES HEIDENHAIN GmbH<br />

D~83292Traunreut~ S2((08669) 31-O SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>1<strong>415</strong><br />

01.09.1995<br />

Kundendienst Paw 9<br />

A = Signal amplitude error<br />

B = Signal frequency error<br />

C = Error with distance-coded scale<br />

Y = CPU number 1 = main processor<br />

2 = geometry processor<br />

3 = CLP processor<br />

Possible error causes:<br />

Encoder not connected<br />

Cable damaged<br />

Glass scale contaminated or damaged<br />

- Scanning head defective<br />

Encoder monitoring system defective<br />

Wrong reference mark spacing entered with distance-coded<br />

linear encoders (counting error caused by the measuring<br />

system or the LOGIC UNIT)<br />

Temoerature inside the LOGIC UNIT has exceeded + 70” C<br />

YX= I( I, Emergency-stop test<br />

1) 2. Emergency-stop test<br />

1. 3. Emergency-stop test<br />

Error during the test routine for the output “Control Ready for<br />

Operation” (see section 17.4)<br />

This error message is only generated if the marker 2815 is set<br />

without additional marker CM2924 M3023).<br />

Marke 2924<br />

I<br />

to<br />

Marke 3023<br />

r 7<br />

and marker 2815 set<br />

1) Instead of “PLC: ERROR 00 to 99” another dialog may be displayed with customized<br />

PLC programs. For further information, please contact your machine tool manufacturer.