22.10.2013 Views

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

Service Manual TNC 407 / TNC 415 - heidenhain - DR. JOHANNES ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Kundendienst<br />

HEIDENHAIN<br />

X21 Data Interface RS 232C<br />

see section 5.1.4 X21<br />

X22 Data Interface RS 422<br />

see section 5.1.4 X22<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 18<br />

X23 Handwheel HR 13Qi330<br />

see section 5.1.4 X23<br />

5.1.7. 6Pin Layout: PLC GRAPHICS BOARD <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

x41 PLC output<br />

Flange socket with female insert (37.pin)<br />

Pin No. Assignment<br />

1 00<br />

? I “l<br />

9 08<br />

,I- I “Q<br />

11 010<br />

12 011<br />

13 012<br />

14 013<br />

16 ,- I ma _,<br />

16 015<br />

17 016<br />

18 017<br />

19 018<br />

ran 23 022<br />

25 I 0244’<br />

26 0254’<br />

27 0264’<br />

X42 PLC input<br />

Flange socket with female insert 137.pin)<br />

Pin No. 1 Assignment<br />

2 II<br />

I /^<br />

s I IL<br />

4 13: acknowledgement for test<br />

“Control Ready for Operation”<br />

._<br />

8 17<br />

23 122<br />

24 123<br />

25 124<br />

1) Internal test potential for tests<br />

2) External power supply for the outputs that can be switched off. Connect preferably via connector X44, pin 1.<br />

3) External reference potential for the PLC supply. Connect preferably via X44, pin 3.<br />

4) Cannot be switched off via EMERGENCY STOP.