Spindle<br />
Function MP A B C D E F Input AE-6<br />
No. Bit Entry Value<br />
Output of the spindle speed 3010 Š Š Š Š Š Š 0 = spindle speed not output 6<br />
coded 1 = only if speed changes<br />
2 = with every TOOL CALL<br />
analogue 3 = gear switching signal only if gear range<br />
changes<br />
4 = gear switching signal with every<br />
TOOL CALL<br />
5 = no gear switching signal<br />
regulated spindle for orientation 6 = gear switching signal only if gear range<br />
changes<br />
7 = gear switching signal with every<br />
TOOL CALL<br />
8 = no gear switching signal<br />
Output of an analogue voltage at<br />
the analogue output of the spindle<br />
(only if MP3010 < 3)<br />
Feed rate that corresponds to an<br />
analogue voltage of 10V<br />
(only if MP3011 = 1)<br />
3011 -<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Š<br />
Š<br />
Š<br />
-<br />
Š<br />
Š<br />
Š<br />
Š<br />
0 = no function<br />
1 = voltage is proportional to the current feed<br />
rate<br />
2 = voltage defined via PLC (module 9130)<br />
3 = voltage defined via M-function<br />
(M200 - M204)<br />
3012 - - - - Š Š 0 to 300 000 [mm/min] 0<br />
RH<br />
1.0 <strong>TNC</strong> <strong>407</strong>/<strong>415</strong> Machine Parameters MP 3010 - MP 3012 08.05.95 10.2 18<br />