Kundendienst<br />

HEIDENHAIN<br />

SERVICE MANUAL <strong>TNC</strong> <strong>407</strong>/<strong>415</strong><br />

Issue: 01.09.1995<br />

Page 75<br />

When the override potentiometer is turned to the right, the control outputs an analog voltage which is increased<br />

proportionally to the servo lag up to IOV max. The control is operating correctly if a voltage of<br />

IOV * O.lV can be measured at the test adaptor with the multimeter. If no voltage can be measured, switch<br />

off the main switch, disconnect the nominal value line from the servo amplifier and test for short-circuit. If the<br />

nominal value line is in order, connect the connector X8 to the LE again (leave the nominal value line disconnected),<br />

switch on the main switch and repeat the measurement with reference mark traverse. If an<br />

analog voltage can be measured now, the control is operating correctly. If no voltage can be measured,<br />

the analog output of the LE is probably defective.<br />

15.2.1 Checking the Analog Outputs: Meas,urement Setup<br />

Multimeter<br />

X8 Nominal Value Output 1,2,3,4,5, S<br />

Flange socket with female insert (15-pin)<br />

Test Adaptor