12.07.2015 Views

Electrical Power for Valdez and the Copper River Basin-1981

Electrical Power for Valdez and the Copper River Basin-1981

Electrical Power for Valdez and the Copper River Basin-1981

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6. ENDANGERED AND THREATENED SPECIES:No endangered or threatened flora <strong>and</strong> fauna, as listed in <strong>the</strong> FederalRegister, Vol. 44, No. 12, 17 January 1979, "List of Endangered <strong>and</strong>Threatened Wildlife <strong>and</strong> Plants" <strong>and</strong> subsequent updates, would be impactedby <strong>the</strong> proposed project. No critical habitat would be destroyed ormodi fied which would jeopardize <strong>the</strong> continued existence of an endangeredor threatened species.7. WETLANDS:Wetl<strong>and</strong> species impacted by this proposal include: rockweed (Fucusdisticus) <strong>and</strong> coraline algae. The project site is not considered to be aproductively vegetated wetl<strong>and</strong>. This project would not adversely impact<strong>the</strong> wetl<strong>and</strong> resource.8. SUBMERGED VEGETATION:The project site is vegetated with submerged vegetation. The followingspecies are located on <strong>the</strong> site: rockweed <strong>and</strong> coraline algae. Thisproject would not adversely impact this wetl<strong>and</strong> resource.9. APPROPRIATE ALTERNATIVES:a. No Action: The no action alternative may cause erosion <strong>and</strong> scourin both Port <strong>Valdez</strong> <strong>and</strong> Allison Creek. This alternative would not beenvironmentally acceptable.b. Reduced Fill Size: The fill is at <strong>the</strong> smallest practicable size.c. Modi fy Fill Location or Dimensions: The location is below <strong>the</strong>outfall at <strong>the</strong> MHHN level <strong>and</strong> cannot be located at any o<strong>the</strong>r site.10. WATER DEPENDENCY:The purpose of <strong>the</strong> project is water dependent or water oriented.activities taking place on <strong>the</strong> fill are water oriented in nature.is a water dependent need <strong>for</strong> <strong>the</strong> proposed project.11. DISPOSAL SITE SELECTION:AllThereThe disposal site has been selected to be <strong>the</strong> least environmentallydamaging. There are no alternate disposal sites available which are lessenvironmentally sensitive <strong>and</strong> still feasible <strong>for</strong> <strong>the</strong> proposed project.The disposal site has been limited to its smallest practical size.3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!