P36 is determined as follows:<br />

If the frame is 13 bits wide, there are 2 13 = 8192 SSI steps per revolution, which must be equal to 1024*4*10 incremental<br />

steps.<br />

2 13 = 8192 SSI steps = 1024*4*10 incremental steps<br />

The ratio is then equal to:<br />

SSI steps 1024 * 4 * 10 40<br />

= =<br />

inc steps 8192 8<br />

or any other combination giving an equivalent ratio.<br />

5.9.3 Other Type of Sensor (Incremental and SSI)<br />

Words 00-63 are not used. They can be set to any value.<br />