P37 P38 P39 P84 P100 P110 P111 P112<br />

Word N1<br />

Sets the communication <strong>parameter</strong>s and notation type (Intel or Motorola). The default value is $15.<br />

Bit 7<br />

Bit 0<br />

Parity:<br />

- bit a 1: parity,<br />

- bit a 0: no parity.<br />

Parity type:<br />

- bit a 1: even parity,<br />

- bit a 0: odd parity.<br />

Number of stop bits:<br />

Bit 3<br />

0<br />

0<br />

1<br />

1<br />

Data rates<br />

Bit 6<br />

0<br />

0<br />

0<br />

1<br />

Bit 2<br />

0<br />

1<br />

0<br />

1<br />

Bit 5<br />

0<br />

1<br />

1<br />

0<br />

Other values<br />

1 stop bit<br />

1 stop bit<br />

1.5 stop bits<br />

2 stop bits<br />

Bit 4<br />

0<br />

0<br />

1<br />

0<br />

Notation type<br />

- bit a 0: Intel format,<br />

- bit a 1: Motorola format.<br />

19200 bauds<br />

4800 bauds<br />

2400 bauds<br />

1200 bauds<br />

9600 bauds<br />

Although the notation type can be set, the value of bit 7 of this word must always be 0 (Intel format).<br />

Word N2<br />

Not significant.<br />

Communication<br />

en-938818/4 10 - 21<br />