P30 P31 P32 P20 P21 P56 P22 P23 P57 P55 P24 P52 P19 P33 P53 P66<br />

This equation can be reformulated to give the maximum tolerated speed:<br />

Vmax =<br />

2R x a ε<br />

T<br />

Example :<br />

Calculation of the maximum tolerated speed for εa = 50 μm, Τ = 60 ms and R = 50 mm.<br />

We have:<br />

2 x 50.10 -3 x 50.10 -6 5.10 -6 2.236<br />

Vmax = –––––––––––––––––– = ––––––– = ––––– = 0.037 m/s, i.e. 2.236 m/min.<br />

60.10 -3 60.10 -3 60<br />

Servo-Control<br />

Programme Parameter<br />

Programme <strong>parameter</strong> E32002 is the image in micrometres of machine <strong>parameter</strong> P52. This <strong>parameter</strong> can be read<br />

and written and retains the last value programmed after a reset.<br />