P30 P31 P32 P20 P21 P56 P22 P23 P57 P55 P24 P52 P19 P33 P53 P66<br />

This value is called EMAX.<br />

The practical equation for EMAX is:<br />

EMAX = VMAX x Τ x 11/10/k<br />

Where:<br />

- Τ is the time constant of the position servo-loop (in ms),<br />

- VMAX is the maximum speed on the axis (in mm/s or deg/s).<br />

Coefficient k can take on the following values:<br />

Internal measurement Coefficient k<br />

1/10 mm 100<br />

1/100 mm 10<br />

μm 1<br />

1/10 μm 0.1<br />

1/100 μm 0.01<br />

1/10000 deg 0.1<br />

Example<br />

Calculation of EMAX for the axis at physical address 0 (VMAX = 100 mm/s, Τ = 60 ms, internal unit μm).<br />

EMAX = 100 x 60 x 1 x 11/10 = 6600<br />

Word N0 6600<br />

Servo-Control<br />

UNI-TE request (see UNI-TE Protocol User’s Manual)<br />

The maximum following errors can be modified by a UNI-TE request. A reset (<strong>CN</strong>C reset) resets the <strong>CN</strong>C to the state<br />

specified by P23.<br />