13.2.5 Check of a Parameter Table Unloaded Into a Peripheral<br />

Parameter Integration Tool<br />

After unloading a <strong>parameter</strong> table into a peripheral, it is necessary to check that the data saved are the same as the<br />

initial data.<br />

Requirement<br />

Peripheral ready to send the data saved.<br />

«MACHINE SETUP DATA» menu displayed.<br />

Actions<br />

Set the peripheral to unload mode.<br />

$<br />

Select «VERIFY» ☞ 4<br />

The cursor moves to line 4 and the message «READY?» is displayed on the dialog line.<br />

Enter. ☞ Y<br />

Run the unload procedure on the peripheral side.<br />

The <strong>parameter</strong>s are listed on the <strong>CN</strong>C screen by increasing order, preceded by «(VERI)».<br />

At the end of the check, if no errors were detected, the «MACHINE SETUP DATA» menu is redisplayed with the cursor<br />

on item 0, «DISPLAY».<br />

Otherwise, the system stops on the <strong>parameter</strong> with an error and the message «FILE ERROR» (INCORRECT TAPE?)<br />

is displayed on the dialog line. Repeat the table unload procedure (see 13.2.4). If the error persists, check the link<br />

between the <strong>CN</strong>C and the peripheral and the communication <strong>parameter</strong>s.<br />

en-938818/4 13 - 13<br />